Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS. / Saji, Nikitha Susan; Wielandt, Daniel Kim Peel; Paton, Chad; Bizzarro, Martin.

In: Journal of Analytical Atomic Spectrometry, Vol. 31, No. 7, 2016, p. 1490-1504.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Saji, NS, Wielandt, DKP, Paton, C & Bizzarro, M 2016, 'Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS', Journal of Analytical Atomic Spectrometry, vol. 31, no. 7, pp. 1490-1504. https://doi.org/10.1039/c6ja00064a

APA

Saji, N. S., Wielandt, D. K. P., Paton, C., & Bizzarro, M. (2016). Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS. Journal of Analytical Atomic Spectrometry, 31(7), 1490-1504. https://doi.org/10.1039/c6ja00064a

Vancouver

Saji NS, Wielandt DKP, Paton C, Bizzarro M. Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS. Journal of Analytical Atomic Spectrometry. 2016;31(7):1490-1504. https://doi.org/10.1039/c6ja00064a

Author

Saji, Nikitha Susan ; Wielandt, Daniel Kim Peel ; Paton, Chad ; Bizzarro, Martin. / Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS. In: Journal of Analytical Atomic Spectrometry. 2016 ; Vol. 31, No. 7. pp. 1490-1504.

Bibtex

@article{0b9a689dc72a418fa8c92307ec121d7b,
title = "Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS",
abstract = "We report novel techniques allowing the measurement of Nd-isotope ratios with unprecedented accuracy and precision by multi-collector inductively coupled plasma mass spectrometry. Using the new protocol, we have measured the Nd-isotopic composition of rock and synthetic Nd standards as well as that of the Allende carbonaceous chondrite. Analyses of BCR-2, BHVO-2 and GSP-2 rock standards yield mass-independent compositions identical to the JNdi-1 Nd-reference standard, with an external reproducibility of 2.4, 1.6, 1.6 and 3.5 ppm respectively, on μ142Nd, μ145Nd, μ146Nd and μ150Nd (μ representing the ppm-deviation of the ratios from JNdi-1) using 148Nd/144Nd for internal normalization. This represents an improvement in precision by a factor of 2, 7 and 9 respectively for μ142Nd, μ145Nd and μ150Nd. Near-quantitative recovery from purification chemistry and sample-standard bracketing allow for the determination of mass-dependent Nd-isotopic composition of samples. Synthetic standards, namely La Jolla and AMES, record mass-dependent variability of up to 1.2 ϵ per atomic mass unit and mass-independent compositions resolvable by up to 3 ppm for μ142Nd and 8 ppm for μ150Nd, relative to JNdi-1. The mass-independent compositions are consistent with equilibrium mass fractionation during purification. The terrestrial rock standards define a uniform stable ϵ145Nd of -0.24 ± 0.19 (2SD) relative to JNdi-1, indistinguishable from the mean Allende ϵ145Nd of -0.19 ± 0.09. We consider this value to represent the mass-dependent Nd-isotope composition of Bulk Silicate Earth (BSE). The modest mass-dependent fractionation of JNdi-1 relative to BSE results in potential effects on mass-independent composition that cannot be resolved within the reproducibility of our analyses when correcting for natural and instrumental mass fractionation by kinetic law, making it a suitable reference standard for analysis of unknowns. Analysis of Allende (CV3) carbonaceous chondrite returns an average μ142Nd deficit of -30.1 ± 3.7 ppm in agreement with previous studies. The apparent deficit is, however, lowered to -23.8 ± 4.0 ppm while normalizing to 148Nd/144Nd instead of 146Nd/144Nd. We interpret this as the effect of a possible nucleosynthetic anomaly of -6.3 ± 0.5 ppm in μ146Nd. As 142Nd and 146Nd are both s-process-dominated nuclides, this hints at the possibility that terrestrial μ142Nd excess may not reflect 146Sm decay as widely accepted.",
author = "Saji, {Nikitha Susan} and Wielandt, {Daniel Kim Peel} and Chad Paton and Martin Bizzarro",
year = "2016",
doi = "10.1039/c6ja00064a",
language = "English",
volume = "31",
pages = "1490--1504",
journal = "Journal of Analytical Atomic Spectrometry",
issn = "0267-9477",
publisher = "Royal Society of Chemistry",
number = "7",

}

RIS

TY - JOUR

T1 - Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS

AU - Saji, Nikitha Susan

AU - Wielandt, Daniel Kim Peel

AU - Paton, Chad

AU - Bizzarro, Martin

PY - 2016

Y1 - 2016

N2 - We report novel techniques allowing the measurement of Nd-isotope ratios with unprecedented accuracy and precision by multi-collector inductively coupled plasma mass spectrometry. Using the new protocol, we have measured the Nd-isotopic composition of rock and synthetic Nd standards as well as that of the Allende carbonaceous chondrite. Analyses of BCR-2, BHVO-2 and GSP-2 rock standards yield mass-independent compositions identical to the JNdi-1 Nd-reference standard, with an external reproducibility of 2.4, 1.6, 1.6 and 3.5 ppm respectively, on μ142Nd, μ145Nd, μ146Nd and μ150Nd (μ representing the ppm-deviation of the ratios from JNdi-1) using 148Nd/144Nd for internal normalization. This represents an improvement in precision by a factor of 2, 7 and 9 respectively for μ142Nd, μ145Nd and μ150Nd. Near-quantitative recovery from purification chemistry and sample-standard bracketing allow for the determination of mass-dependent Nd-isotopic composition of samples. Synthetic standards, namely La Jolla and AMES, record mass-dependent variability of up to 1.2 ϵ per atomic mass unit and mass-independent compositions resolvable by up to 3 ppm for μ142Nd and 8 ppm for μ150Nd, relative to JNdi-1. The mass-independent compositions are consistent with equilibrium mass fractionation during purification. The terrestrial rock standards define a uniform stable ϵ145Nd of -0.24 ± 0.19 (2SD) relative to JNdi-1, indistinguishable from the mean Allende ϵ145Nd of -0.19 ± 0.09. We consider this value to represent the mass-dependent Nd-isotope composition of Bulk Silicate Earth (BSE). The modest mass-dependent fractionation of JNdi-1 relative to BSE results in potential effects on mass-independent composition that cannot be resolved within the reproducibility of our analyses when correcting for natural and instrumental mass fractionation by kinetic law, making it a suitable reference standard for analysis of unknowns. Analysis of Allende (CV3) carbonaceous chondrite returns an average μ142Nd deficit of -30.1 ± 3.7 ppm in agreement with previous studies. The apparent deficit is, however, lowered to -23.8 ± 4.0 ppm while normalizing to 148Nd/144Nd instead of 146Nd/144Nd. We interpret this as the effect of a possible nucleosynthetic anomaly of -6.3 ± 0.5 ppm in μ146Nd. As 142Nd and 146Nd are both s-process-dominated nuclides, this hints at the possibility that terrestrial μ142Nd excess may not reflect 146Sm decay as widely accepted.

AB - We report novel techniques allowing the measurement of Nd-isotope ratios with unprecedented accuracy and precision by multi-collector inductively coupled plasma mass spectrometry. Using the new protocol, we have measured the Nd-isotopic composition of rock and synthetic Nd standards as well as that of the Allende carbonaceous chondrite. Analyses of BCR-2, BHVO-2 and GSP-2 rock standards yield mass-independent compositions identical to the JNdi-1 Nd-reference standard, with an external reproducibility of 2.4, 1.6, 1.6 and 3.5 ppm respectively, on μ142Nd, μ145Nd, μ146Nd and μ150Nd (μ representing the ppm-deviation of the ratios from JNdi-1) using 148Nd/144Nd for internal normalization. This represents an improvement in precision by a factor of 2, 7 and 9 respectively for μ142Nd, μ145Nd and μ150Nd. Near-quantitative recovery from purification chemistry and sample-standard bracketing allow for the determination of mass-dependent Nd-isotopic composition of samples. Synthetic standards, namely La Jolla and AMES, record mass-dependent variability of up to 1.2 ϵ per atomic mass unit and mass-independent compositions resolvable by up to 3 ppm for μ142Nd and 8 ppm for μ150Nd, relative to JNdi-1. The mass-independent compositions are consistent with equilibrium mass fractionation during purification. The terrestrial rock standards define a uniform stable ϵ145Nd of -0.24 ± 0.19 (2SD) relative to JNdi-1, indistinguishable from the mean Allende ϵ145Nd of -0.19 ± 0.09. We consider this value to represent the mass-dependent Nd-isotope composition of Bulk Silicate Earth (BSE). The modest mass-dependent fractionation of JNdi-1 relative to BSE results in potential effects on mass-independent composition that cannot be resolved within the reproducibility of our analyses when correcting for natural and instrumental mass fractionation by kinetic law, making it a suitable reference standard for analysis of unknowns. Analysis of Allende (CV3) carbonaceous chondrite returns an average μ142Nd deficit of -30.1 ± 3.7 ppm in agreement with previous studies. The apparent deficit is, however, lowered to -23.8 ± 4.0 ppm while normalizing to 148Nd/144Nd instead of 146Nd/144Nd. We interpret this as the effect of a possible nucleosynthetic anomaly of -6.3 ± 0.5 ppm in μ146Nd. As 142Nd and 146Nd are both s-process-dominated nuclides, this hints at the possibility that terrestrial μ142Nd excess may not reflect 146Sm decay as widely accepted.

UR - http://www.scopus.com/inward/record.url?scp=84976897372&partnerID=8YFLogxK

U2 - 10.1039/c6ja00064a

DO - 10.1039/c6ja00064a

M3 - Journal article

AN - SCOPUS:84976897372

VL - 31

SP - 1490

EP - 1504

JO - Journal of Analytical Atomic Spectrometry

JF - Journal of Analytical Atomic Spectrometry

SN - 0267-9477

IS - 7

ER -

ID: 163775574